格力LF-12WAK分體立柜式房間空調器故障代碼﹕E1﹑冷凝器前有障礙物﹑控制回路巽常﹑三相電源缺相﹑室外環境溫度高于43度時開始制冷﹑工作電流過大使過護器動作或高壓管壓力過大使高壓開關動作
Fault codes of Gree LF-12WAK split vertical cabinet room air conditioner: E1, obstacles in front of condenser, control circuit, three-phase power supply absence, starting refrigeration when outdoor ambient temperature is higher than 43 degrees, excessive working current causes over-protector action or high-voltage tube pressure causes high-voltage switch action.
E2 ﹑室內風機不轉或風口堵住﹑室內環境溫度低于18度﹑管溫感溫頭折斷﹑管溫感溫頭插頭沒插好﹑控制回路巽常﹑電容C7漏電格力空調服務,E1一般是外機問題 過欠流 過欠壓 散熱不良!
E2, the indoor fan does not turn or the tuyere is blocked, the indoor ambient temperature is below 18 degrees, the tube temperature sensor head is broken, the plug of the tube temperature sensor head is not inserted properly, the control circuit is normal, the capacitor C7 leakage grid air conditioning maintenance, E1 is generally the problem of the external machine over undercurrent over undervoltage and bad heat dissipation!
格力KF-60L WAK分體立柜式房間空調器故障代碼﹕E1 ,冷凝器前有障礙物﹑控制回路巽常﹑室外環境溫度高于43度時開始制冷﹑高壓管壓力過大使高壓開關動作
Fault Code of Griffith KF-60L WAK Separated Vertical Cabinet Room Air Conditioner: E1, High Voltage Switch Actions when there are obstacles in front of condenser, control circuit is normal, outdoor ambient temperature is higher than 43 degrees, and high pressure pipe pressure is too high.
E2 ,室內風機不轉或風口堵住﹑室內環境溫度低于18度﹑管溫感溫頭折斷﹑管溫感溫頭插頭沒插好﹑控制回路巽常﹑電容C7漏電
E2, Indoor fan not turning or tuyere blocking, indoor ambient temperature below 18 degrees, pipe temperature sensor head broken, pipe temperature sensor plug not inserted properly, control circuit normal, capacitor C7 leakage